搜索
Search
Generic filters

TM-201 Transmittance Smoke Meter

1、Smoke Meter Adopting the measurement principle of taking style (shunt type) to measure the impermeability of motor vehicle exhaust.
2、TM-201 Transmissive smoke meter complies with the national standard GB 3847-2018 “Emission limits and measurement methods for diesel vehicles (free acceleration method and loaded deceleration method)”.
3、TM-201 Transmittance Smoke Meter it is suitable for use by environmental protection departments, motor vehicle testing stations, automobile manufacturers, automobile repair shops and other units.

Motor vehicle inspectionClick the button below to get in touch with us!

Product introduction

1、Smoke Meter Adopting the measurement principle of taking style (shunt type) to measure the impermeability of motor vehicle exhaust.
2、TM-201 Transmissive smoke meter complies with the national standard GB 3847-2018 “Emission limits and measurement methods for diesel vehicles (free acceleration method and loaded deceleration method)”.
3、TM-201 Transmittance Smoke Meter it is suitable for use by environmental protection departments, motor vehicle testing stations, automobile manufacturers, automobile repair shops and other units.

Product features

☆ Smoke meter with “air curtain” protection technology to protect the optical system from contamination by exhaust fumes. Constant temperature control of the measurement chamber to prevent condensation of water in the exhaust air, which could affect the measurement results.
☆Smoke meter with real-time testing and free acceleration testing.
☆ With oil temperature testing function.
☆ Large LCD display with clear font.
☆Adopting graphic display with friendly interface.
☆The smoke meter is equipped with RS485 interface to communicate with external computer.
☆ Optional built-in micro printer.
☆Optional tacho analyser to measure engine speed.

Technical specifications

Measurement range

Absorption ratio (Ns)(0~99.9)%
Light absorption coefficient (K)(0~16.08) m-1
Rotational speed(500~6000) r/min
Oil temperature(0~200) ℃
Flue gas temperature(0~150) ℃
Corresponding absorption ratio N measurement range is (0 to 98.6)%

 

 

Error of measurement

Absorption ratio (Ns)±2.0%
Rotational speed±1%
Oil temperature±2℃
Flue gas temperature±2℃

 

Resolving power

Absorption ratio (Ns)0.1%
Light absorption coefficient (K)0.01 m-1
Rotational speed1 r/min
Oil temperature1 ℃
Flue gas temperature1 ℃

 

Other parameters

Working conditionsProduct specifications
Pneumatic pressure60.0KPa~110.0KPaWorking powerAC 220V±22V,50Hz±1HzPower rating150W
Temperature-5 ℃~50 ℃Upper unit size353×248×210 mmLower unit size525×170×332 mm
Relative humidity≤95%Upper unit weightApprox. 5.5kgLower unit weightApprox. 7.5kg
Effective length of optical channel215 mmEquivalent length of optical channel430mm

 

Related content:Motor Vehicle Exhaust Testing Equipment

Online shop:Alibaba

Contact us